| 100 | 1 | ▼a Xu, Zhonglin. |
| 245 | 1 0 | ▼a Dynamic isolation technologies in negative pressure isolation wards ▼h [electronic resource] / ▼c Zhonglin Xu, Bin Zhou. |
| 260 | ▼a Singapore : ▼b Springer, ▼c c2017. | |
| 300 | ▼a 1 online resource (x, 216 p.) : ▼b ill. (some col.). | |
| 500 | ▼a Title from e-Book title page. | |
| 504 | ▼a Includes bibliographical references. | |
| 505 | 0 | ▼a Importance of negative pressure isolation ward -- Three misunderstandings in design process of negative pressure isolation ward -- Principle and technology of dynamic isolation -- Air distribution design in negative pressure isolation ward -- Determination of air change rate in negative pressure isolation ward -- Safety of exhaust and return air is prerequisite -- Design essentials for negative pressure isolation ward. |
| 520 | ▼a This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach. This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas. | |
| 530 | ▼a Issued also as a book. | |
| 538 | ▼a Mode of access: World Wide Web. | |
| 650 | 0 | ▼a Hospital buildings ▼x Heating and ventilation. |
| 650 | 0 | ▼a Isolation (Hospital care). |
| 650 | 2 | ▼a Infection Control ▼x methods. |
| 700 | 1 | ▼a Zhou, Bin. |
| 856 | 4 0 | ▼u https://oca.korea.ac.kr/link.n2s?url=https://doi.org/10.1007/978-981-10-2923-3 |
| 945 | ▼a KLPA | |
| 991 | ▼a E-Book(소장) |
소장정보
| No. | 소장처 | 청구기호 | 등록번호 | 도서상태 | 반납예정일 | 예약 | 서비스 |
|---|---|---|---|---|---|---|---|
| No. 1 | 소장처 중앙도서관/e-Book 컬렉션/ | 청구기호 CR 614.46 | 등록번호 E14017223 | 도서상태 대출불가(열람가능) | 반납예정일 | 예약 | 서비스 |
컨텐츠정보
책소개
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach.
This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
New feature
This book presents novel design principles and technologies for dynamic isolation based on experimental studies. These approaches have now become the local standard in Beijing and are currently being promoted for use nationwide. Further, the book provides details of measures and guidelines for the design process. Departing from the traditional understanding that isolation wards should be designed with high negative pressure, airtight doors and fresh air, it establishes the basis for designing biological clean rooms, including isolation wards, using a simple and convenient scientific approach.
This book is intended for designers, engineers, researchers, hospital management staff and graduate students in heating ventilation air conditioning (HVAC), air cleaning technologies and related areas.
정보제공 :
목차
Importance of negative pressure isolation ward.- Three misunderstandings in design process of negative pressure isolation ward.- Principle and technology of dynamic isolation.- Air distribution design in negative pressure isolation ward.- Determination of air change rate in negative pressure isolation ward.- Safety of exhaust and return air is prerequisite.- Design essentials for negative pressure isolation ward.
정보제공 :